{"id":295324,"date":"2026-08-30T12:14:10","date_gmt":"2026-08-30T10:14:10","guid":{"rendered":"https:\/\/drain-master.de\/2026\/08\/30\/storing-and-caring-for-a-ph-electrode-the-5-costliest-mistakes\/"},"modified":"2026-08-30T12:14:10","modified_gmt":"2026-08-30T10:14:10","slug":"storing-and-caring-for-a-ph-electrode-the-5-costliest-mistakes","status":"publish","type":"post","link":"https:\/\/drain-master.de\/en\/2026\/08\/30\/storing-and-caring-for-a-ph-electrode-the-5-costliest-mistakes\/","title":{"rendered":"Storing and Caring for a pH Electrode: the 5 Costliest Mistakes"},"content":{"rendered":"<article>\n<p class=\"intro\">Most pH electrodes do not break during use, they break between two measurements. Dry in a drawer, parked in distilled water or polished clean with a cloth: three well meant habits, three ways to kill a sensor early.<\/p>\n<h2>What you are actually holding<\/h2>\n<p>Two delicate parts sit at the bottom of your meter. First the <strong>glass membrane<\/strong>: a wafer thin glass bulb whose surface needs a water saturated gel layer to measure at all. Once that layer dries out, the electrode responds sluggishly, drifts, or refuses to calibrate.<\/p>\n<p>Second the <strong>junction<\/strong>: a tiny porous spot in the shaft through which the reference side keeps contact with the sample, usually visible as a lighter dot or ring. If it clogs, the circuit collapses, readings become unstable and wander off even though the glass looks perfect.<\/p>\n<p>Both parts need the same thing: <strong>ions and moisture<\/strong>. That is exactly what a potassium chloride solution provides.<\/p>\n<h2>The most important rule first: never store in distilled water<\/h2>\n<p>This is the mistake almost everyone makes once, because it feels right. Distilled and demineralised water is ion poor, which means it <em>wants<\/em> to take on ions. Leave an electrode in it and the water pulls electrolyte out of the interior through the junction. The reference side depletes, and what you measure afterwards is slowly drifting numbers with no foundation.<\/p>\n<p>Tap water is no solution either: it carries hardness minerals and a pH value of its own that changes the membrane over weeks.<\/p>\n<p><strong>The right answer is a 3 molar potassium chloride solution (3M KCl).<\/strong> It keeps the gel layer moist, the junction clear and the reference side in balance.<\/p>\n<div class=\"woocommerce columns-1 \"><ul class=\"products columns-1\">\n<li class=\"product type-product post-85412 status-publish first onbackorder product_cat-solutions product_cat-ph-value has-post-thumbnail taxable shipping-taxable purchasable product-type-simple\">\n\t<a href=\"https:\/\/drain-master.de\/en\/product\/apera-3m-kcl-electrode-storage-solution-250ml\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><div class=\"woocommerce-image__wrapper\"><a href=\"https:\/\/drain-master.de\/en\/product\/apera-3m-kcl-electrode-storage-solution-250ml\/\" title=\"Apera 3M KCl electrode storage solution 250ml\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><div class=\"shoptimizer-plp-carousel-container\"><div class=\"shoptimizer-plp-image-wrapper\"><img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-300x300.jpg\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Apera 3M KCl electrode storage solution\" srcset=\"https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-300x300.jpg 300w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-600x600.jpg 600w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-1024x1024.jpg 1024w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-768x768.jpg 768w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-1536x1536.jpg 1536w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-990x990.jpg 990w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-441x441.jpg 441w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-100x100.jpg 100w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-800x800.jpg 800w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL-150x150.jpg 150w, https:\/\/drain-master.de\/wp-content\/uploads\/2024\/07\/apera_3M_KCL.jpg 2000w\" sizes=\"(max-width: 360px) 147px, (max-width: 300px) 100vw, 300px\" \/>\t\t\t\n\t<\/div><\/div><\/a><\/div><div class=\"woocommerce-card__header\">\t\t\t\t\t\t<p class=\"product__categories\"><a href=\"https:\/\/drain-master.de\/en\/product-category\/measuring-devices\/solutions\/\" rel=\"tag\">Calibration Solutions<\/a>, <a href=\"https:\/\/drain-master.de\/en\/product-category\/measuring-devices\/ph-value\/\" rel=\"tag\">pH Meters<\/a><\/p>\t\t\t\t<div class=\"woocommerce-loop-product__title\"><a tabindex=\"0\" href=\"https:\/\/drain-master.de\/en\/product\/apera-3m-kcl-electrode-storage-solution-250ml\/\" aria-label=\"Apera 3M KCl electrode storage solution 250ml\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\">Apera 3M KCl electrode storage solution 250ml<\/a><\/div><\/a><p class=\"price\"><span class=\"woocommerce-Price-amount amount\"><bdi>12,40&nbsp;<span class=\"woocommerce-Price-currencySymbol\" translate=\"no\">&euro;<\/span><\/bdi><\/span><\/p><\/a><a href=\"\/en\/wp-json\/wp\/v2\/posts\/295324?add-to-cart=85412\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_85412\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"85412\" data-product_sku=\"28APE190316\" aria-label=\"Add to cart: &ldquo;Apera 3M KCl electrode storage solution 250ml&rdquo;\" rel=\"nofollow\" data-success_message=\"&ldquo;Apera 3M KCl electrode storage solution 250ml&rdquo; has been added to your cart\" role=\"button\">Add to cart<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_85412\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n\t\t\t<input type=\"hidden\" class=\"pmwProductId\" data-id=\"85412\">\n\t\t\t\t\t<script data-cfasync=\"false\">\n\t\t\t(window.pmwDataLayer = window.pmwDataLayer || {}).products                = window.pmwDataLayer.products || {};\n\t\t\twindow.pmwDataLayer.products[85412] = {\"id\":\"85412\",\"sku\":\"28APE190316\",\"price\":12.4,\"brand\":\"Apera Instruments\",\"quantity\":1,\"dyn_r_ids\":{\"post_id\":\"85412\",\"sku\":\"28APE190316\",\"gpf\":\"woocommerce_gpf_85412\",\"gla\":\"gla_85412\",\"dm_de_post_id\":\"85060\"},\"is_variable\":false,\"type\":\"simple\",\"name\":\"Apera 3M KCl electrode storage solution 250ml\",\"category\":[\"Calibration Solutions\",\"pH Meters\"],\"is_variation\":false};\n\t\t\t\t\twindow.pmw_product_position = window.pmw_product_position || 1;\n\t\twindow.pmwDataLayer.products[85412]['position'] = window.pmw_product_position++;\n\t\t\t\t<\/script>\n\t\t<\/div><\/li>\n<\/ul>\n<\/div>\n<h2>How to store it properly<\/h2>\n<ol>\n<li><strong>Short breaks (hours to days):<\/strong> a few drops of <a href=\"https:\/\/drain-master.de\/en\/product\/apera-3m-kcl-electrode-storage-solution-250ml\/\">Apera 3M KCl electrode storage solution 250ml<\/a> in the protective cap, cap on, done. What matters is that the bulb and the junction are wetted.<\/li>\n<li><strong>Longer breaks (weeks to months):<\/strong> store the same way, but check the liquid regularly. It evaporates, and every four to six months it should be replaced. A glance at every battery change is enough.<\/li>\n<li><strong>Always upright.<\/strong> The junction has to sit fully in the liquid. Lay the electrode on its side and exactly the spot that matters dries out.<\/li>\n<li><strong>No frost, no radiator.<\/strong> Room temperature is ideal. If the solution freezes, it cracks the glass membrane.<\/li>\n<\/ol>\n<p>If the electrode has dried out anyway, not all is lost: stand it in KCl solution for a few hours, overnight if in doubt, then recalibrate. After a short dry spell it often recovers fully. After weeks in the dry, some sluggishness usually remains.<\/p>\n<h2>Cleaning: dab, do not rub<\/h2>\n<p>After every measurement the electrode gets rinsed with distilled water, which is exactly right for <em>rinsing<\/em>, just not for storing. Then <strong>dab<\/strong> it carefully with a soft, lint free cloth.<\/p>\n<p>Rubbing is forbidden for two reasons: it leaves fine scratches in the glass and it charges the membrane statically. A statically charged electrode shows readings that wander for minutes, a fault pattern regularly mistaken for a broken device.<\/p>\n<p>For stubborn deposits, the fix depends on the cause:<\/p>\n<ul>\n<li><strong>\u2705 Fertiliser salts and limescale:<\/strong> briefly into dilute acid, then rinse thoroughly and regenerate for several hours in KCl solution.<\/li>\n<li><strong>\u2705 Grease and oil films:<\/strong> mild detergent in warm water, then rinse clean thoroughly.<\/li>\n<li><strong>\u2705 Organic deposits and biofilm:<\/strong> a commercial electrode cleaning solution. Never scrape anything off mechanically.<\/li>\n<\/ul>\n<p>After any cleaning one rule holds without exception: <a href=\"https:\/\/drain-master.de\/en\/2026\/08\/30\/how-to-calibrate-a-ph-meter-6-steps-that-actually-work\/\">recalibrate<\/a>. A cleaned electrode has different characteristics from the dirty one your device was last set up for.<\/p>\n<h2>How to tell it is time for a new one<\/h2>\n<p>A pH electrode is a wear part and with good care typically lasts one to two years. Four signs point to a replacement:<\/p>\n<ul>\n<li><strong>\u2705 Calibration fails repeatedly<\/strong> or the device reports an error although the buffers are fresh.<\/li>\n<li><strong>\u2705 The reading takes forever<\/strong> to settle, noticeably longer than it used to on the same sample.<\/li>\n<li><strong>\u2705 The display jitters<\/strong> and will not come to rest even after minutes, despite clean rinsing.<\/li>\n<li><strong>\u2705 The junction stays discoloured<\/strong> or blocked even after cleaning and regeneration.<\/li>\n<\/ul>\n<p>Before you throw it away, always check the simple causes first: old buffer solution, tap water for rinsing, a sample that is too cold. Those three explain more supposed electrode failures than actual wear.<\/p>\n<h2>Replace instead of discard<\/h2>\n<p>This is where the device you bought makes the difference. On the <a href=\"https:\/\/drain-master.de\/en\/product\/ph20-value-ph-pocket-meter\/\">Apera PH20 Value pH pocket meter<\/a> the electrode is built in, so at the end of its life the whole device is due. On the 60 series you unscrew it and fit a new one:<\/p>\n<ul>\n<li>for the PH60: the <a href=\"https:\/\/drain-master.de\/en\/product\/apera-ph-replacement-electrode-for-ph60-ph60-e\/\">Apera pH replacement electrode for PH60 (PH60-E)<\/a><\/li>\n<li>for the PC60-Z: the <a href=\"https:\/\/drain-master.de\/en\/product\/pc60-de-replacement-electrode-for-pc60-z\/\">Apera replacement electrode PC60-DE (for PC60-Z)<\/a><\/li>\n<\/ul>\n<p>That is exactly why the step up to the premium class pays off for heavy users. The full calculation is in our <a href=\"https:\/\/drain-master.de\/en\/2026\/08\/30\/apera-ph20-or-ph60-an-honest-comparison\/\">comparison of the PH20 and the PH60<\/a>.<\/p>\n<div class=\"woocommerce columns-1 \"><ul class=\"products columns-1\">\n<li class=\"product type-product post-101354 status-publish first instock product_cat-ph-value product_cat-measuring-devices has-post-thumbnail sale taxable shipping-taxable purchasable product-type-simple\">\n\t<a href=\"https:\/\/drain-master.de\/en\/product\/apera-ph-replacement-electrode-for-ph60-ph60-e\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><div class=\"woocommerce-image__wrapper\"><a href=\"https:\/\/drain-master.de\/en\/product\/apera-ph-replacement-electrode-for-ph60-ph60-e\/\" title=\"Apera pH replacement electrode for PH60 (PH60-E)\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\">\n\t\n\t<div class=\"shoptimizer-plp-carousel-container\"><div class=\"shoptimizer-plp-image-wrapper\"><img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/drain-master.de\/wp-content\/uploads\/2025\/02\/PH60_Probe-2-300x300.png\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"PH60-E 28APE190034\" srcset=\"https:\/\/drain-master.de\/wp-content\/uploads\/2025\/02\/PH60_Probe-2-300x300.png 300w, https:\/\/drain-master.de\/wp-content\/uploads\/2025\/02\/PH60_Probe-2-441x441.png 441w, https:\/\/drain-master.de\/wp-content\/uploads\/2025\/02\/PH60_Probe-2-100x100.png 100w, https:\/\/drain-master.de\/wp-content\/uploads\/2025\/02\/PH60_Probe-2-150x150.png 150w, https:\/\/drain-master.de\/wp-content\/uploads\/2025\/02\/PH60_Probe-2.png 600w\" sizes=\"(max-width: 360px) 147px, (max-width: 300px) 100vw, 300px\" \/>\t\t\t\n\t<\/div><\/div><\/a><\/div><div class=\"woocommerce-card__header\">\t\t\t\t\t\t<p class=\"product__categories\"><a href=\"https:\/\/drain-master.de\/en\/product-category\/measuring-devices\/ph-value\/\" rel=\"tag\">pH Meters<\/a>, <a href=\"https:\/\/drain-master.de\/en\/product-category\/measuring-devices\/\" rel=\"tag\">pH &amp; EC Meters<\/a><\/p>\t\t\t\t<div class=\"woocommerce-loop-product__title\"><a tabindex=\"0\" href=\"https:\/\/drain-master.de\/en\/product\/apera-ph-replacement-electrode-for-ph60-ph60-e\/\" aria-label=\"Apera pH replacement electrode for PH60 (PH60-E)\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\">Apera pH replacement electrode for PH60 (PH60-E)<\/a><\/div><\/a><p class=\"price\"><del aria-hidden=\"true\"><span class=\"woocommerce-Price-amount amount\"><bdi>51,17&nbsp;<span class=\"woocommerce-Price-currencySymbol\" translate=\"no\">&euro;<\/span><\/bdi><\/span><\/del> <span class=\"screen-reader-text\">Original price was: 51,17&nbsp;&euro;.<\/span><ins aria-hidden=\"true\"><span class=\"woocommerce-Price-amount amount\"><bdi>49,99&nbsp;<span class=\"woocommerce-Price-currencySymbol\" translate=\"no\">&euro;<\/span><\/bdi><\/span><\/ins><span class=\"screen-reader-text\">Current price is: 49,99&nbsp;&euro;.<\/span><\/p><\/a><a href=\"\/en\/wp-json\/wp\/v2\/posts\/295324?add-to-cart=101354\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_101354\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"101354\" data-product_sku=\"28APE190034\" aria-label=\"Add to cart: &ldquo;Apera pH replacement electrode for PH60 (PH60-E)&rdquo;\" rel=\"nofollow\" data-success_message=\"&ldquo;Apera pH replacement electrode for PH60 (PH60-E)&rdquo; has been added to your cart\" role=\"button\">Add to cart<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_101354\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n\t\t\t<input type=\"hidden\" class=\"pmwProductId\" data-id=\"101354\">\n\t\t\t\t\t<script data-cfasync=\"false\">\n\t\t\t(window.pmwDataLayer = window.pmwDataLayer || {}).products                = window.pmwDataLayer.products || {};\n\t\t\twindow.pmwDataLayer.products[101354] = {\"id\":\"101354\",\"sku\":\"28APE190034\",\"price\":49.99,\"brand\":\"\",\"quantity\":1,\"dyn_r_ids\":{\"post_id\":\"101354\",\"sku\":\"28APE190034\",\"gpf\":\"woocommerce_gpf_101354\",\"gla\":\"gla_101354\",\"dm_de_post_id\":\"101350\"},\"is_variable\":false,\"type\":\"simple\",\"name\":\"Apera pH replacement electrode for PH60 (PH60-E)\",\"category\":[\"pH Meters\",\"pH \\u0026amp; EC Meters\"],\"is_variation\":false};\n\t\t\t\t\twindow.pmw_product_position = window.pmw_product_position || 1;\n\t\twindow.pmwDataLayer.products[101354]['position'] = window.pmw_product_position++;\n\t\t\t\t<\/script>\n\t\t<\/div><\/li>\n<\/ul>\n<\/div>\n<h2>The care routine in short<\/h2>\n<ul>\n<li><strong>After every measurement:<\/strong> rinse with distilled water, dab dry, fit the cap with KCl solution.<\/li>\n<li><strong>Before every measuring day:<\/strong> a visual check. Is the cap moist, is the glass clean, is the junction light coloured?<\/li>\n<li><strong>Every 4 to 6 months:<\/strong> replace the KCl solution in the cap.<\/li>\n<li><strong>After cleaning, replacement or a long break:<\/strong> always recalibrate.<\/li>\n<li><strong>Never:<\/strong> store dry, store in distilled water, rub the glass, use the electrode as a stirring rod.<\/li>\n<\/ul>\n<p>And because the best electrode care is worthless if the sample is no good: the DrainMaster collects your runoff cleanly, so you can take a fresh sample instead of measuring from water full of deposits. Our article on <a href=\"https:\/\/drain-master.de\/en\/2026\/04\/12\/monitor-cannabis-drain-its-easy-fast\/\">checking cannabis runoff<\/a> shows how that works.<\/p>\n<div class=\"woocommerce columns-1 \"><ul class=\"products columns-1\">\n<li class=\"product type-product post-2267 status-publish first instock product_cat-coaster product_cat-garden-supplies has-post-thumbnail taxable shipping-taxable purchasable product-type-simple\">\n\t<a href=\"https:\/\/drain-master.de\/en\/product\/drainmaster-drip-stand\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><div class=\"woocommerce-image__wrapper\"><a href=\"https:\/\/drain-master.de\/en\/product\/drainmaster-drip-stand\/\" title=\"DrainMaster incl. drip tray (set size configurable)\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><div class=\"shoptimizer-plp-carousel-container\"><div class=\"shoptimizer-plp-image-wrapper\"><img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2-300x300.jpg\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"DrainMaster Single set\" srcset=\"https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2-300x300.jpg 300w, https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2-1019x1024.jpg 1019w, https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2-768x771.jpg 768w, https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2-1529x1536.jpg 1529w, https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2-990x994.jpg 990w, https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2-441x443.jpg 441w, https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2-100x100.jpg 100w, https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2-150x151.jpg 150w, https:\/\/drain-master.de\/wp-content\/uploads\/2023\/04\/DrainMaster-Set_2.jpg 1991w\" sizes=\"(max-width: 360px) 147px, (max-width: 300px) 100vw, 300px\" \/>\t\t\t\n\t<\/div><\/div><\/a><\/div><div class=\"woocommerce-card__header\">\t\t\t\t\t\t<p class=\"product__categories\"><a href=\"https:\/\/drain-master.de\/en\/product-category\/garden-supplies\/coaster\/\" rel=\"tag\">Plant Pot Saucers<\/a>, <a href=\"https:\/\/drain-master.de\/en\/product-category\/garden-supplies\/\" rel=\"tag\">Grow Accessories<\/a><\/p>\t\t\t\t<div class=\"woocommerce-loop-product__title\"><a tabindex=\"0\" href=\"https:\/\/drain-master.de\/en\/product\/drainmaster-drip-stand\/\" aria-label=\"DrainMaster incl. drip tray (set size configurable)\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\">DrainMaster incl. drip tray (set size configurable)<\/a><\/div><\/a><p class=\"price\"><span class=\"woocommerce-Price-amount amount\"><bdi>21,99&nbsp;<span class=\"woocommerce-Price-currencySymbol\" translate=\"no\">&euro;<\/span><\/bdi><\/span><\/p><\/a><a href=\"\/en\/wp-json\/wp\/v2\/posts\/295324?add-to-cart=2267\" aria-describedby=\"woocommerce_loop_add_to_cart_link_describedby_2267\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"2267\" data-product_sku=\"DM-01\" aria-label=\"Add to cart: &ldquo;DrainMaster incl. drip tray (set size configurable)&rdquo;\" rel=\"nofollow\" data-success_message=\"&ldquo;DrainMaster incl. drip tray (set size configurable)&rdquo; has been added to your cart\" role=\"button\">Add to cart<\/a>\t<span id=\"woocommerce_loop_add_to_cart_link_describedby_2267\" class=\"screen-reader-text\">\n\t\t\t<\/span>\n\t\t\t<input type=\"hidden\" class=\"pmwProductId\" data-id=\"2267\">\n\t\t\t\t\t<script data-cfasync=\"false\">\n\t\t\t(window.pmwDataLayer = window.pmwDataLayer || {}).products                = window.pmwDataLayer.products || {};\n\t\t\twindow.pmwDataLayer.products[2267] = {\"id\":\"2267\",\"sku\":\"DM-01\",\"price\":21.99,\"brand\":\"\",\"quantity\":1,\"dyn_r_ids\":{\"post_id\":\"2267\",\"sku\":\"DM-01\",\"gpf\":\"woocommerce_gpf_2267\",\"gla\":\"gla_2267\",\"dm_de_post_id\":\"1813\"},\"is_variable\":false,\"type\":\"simple\",\"name\":\"DrainMaster incl. drip tray (set size configurable)\",\"category\":[\"Plant Pot Saucers\",\"Grow Accessories\"],\"is_variation\":false};\n\t\t\t\t\twindow.pmw_product_position = window.pmw_product_position || 1;\n\t\twindow.pmwDataLayer.products[2267]['position'] = window.pmw_product_position++;\n\t\t\t\t<\/script>\n\t\t<\/div><\/li>\n<\/ul>\n<\/div>\n<h2>Frequently asked questions<\/h2>\n<details style=\"border: 1px solid #e5e7eb; border-radius: 8px; margin-bottom: 8px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; cursor: pointer; font-weight: 600; font-size: 1.05em; background: #fafafa; list-style: none;\">Why must I not store a pH electrode in distilled water?<\/summary>\n<p style=\"padding: 14px 18px; margin: 0; color: #555; line-height: 1.6; border-top: 1px solid #e5e7eb;\">Distilled water is ion poor and therefore pulls electrolyte out of the electrode through the junction. The reference side depletes, readings drift and the electrode ages considerably faster. For rinsing, distilled water is exactly right. For storing, a 3 molar KCl solution belongs in the protective cap.<\/p>\n<\/details>\n<details style=\"border: 1px solid #e5e7eb; border-radius: 8px; margin-bottom: 8px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; cursor: pointer; font-weight: 600; font-size: 1.05em; background: #fafafa; list-style: none;\">My electrode has dried out: is it dead?<\/summary>\n<p style=\"padding: 14px 18px; margin: 0; color: #555; line-height: 1.6; border-top: 1px solid #e5e7eb;\">Not necessarily. Stand it in 3M KCl solution for several hours, overnight if in doubt, then recalibrate over two points. If it was only dry briefly it usually recovers fully. After weeks in the dry a sluggish response often remains that no calibration can remove.<\/p>\n<\/details>\n<details style=\"border: 1px solid #e5e7eb; border-radius: 8px; margin-bottom: 8px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; cursor: pointer; font-weight: 600; font-size: 1.05em; background: #fafafa; list-style: none;\">How often should I change the storage solution?<\/summary>\n<p style=\"padding: 14px 18px; margin: 0; color: #555; line-height: 1.6; border-top: 1px solid #e5e7eb;\">Every four to six months, and immediately if it turns cloudy, shows flakes or has visibly evaporated. The cap is small and holds very little liquid, which is why a glance at every battery change pays off. Topping it up costs cents, a new electrode costs many times that.<\/p>\n<\/details>\n<details style=\"border: 1px solid #e5e7eb; border-radius: 8px; margin-bottom: 8px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; cursor: pointer; font-weight: 600; font-size: 1.05em; background: #fafafa; list-style: none;\">What is the junction and why does it clog?<\/summary>\n<p style=\"padding: 14px 18px; margin: 0; color: #555; line-height: 1.6; border-top: 1px solid #e5e7eb;\">The junction is a small porous spot in the shaft through which the reference side keeps contact with the sample, usually visible as a lighter dot or ring. Salts, limescale, grease or biofilm can block the pores, at which point readings become unstable. Depending on the cause, dilute acid, mild detergent or a cleaning solution helps, followed by several hours of regeneration in KCl.<\/p>\n<\/details>\n<details style=\"border: 1px solid #e5e7eb; border-radius: 8px; margin-bottom: 8px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; cursor: pointer; font-weight: 600; font-size: 1.05em; background: #fafafa; list-style: none;\">May I wipe the glass membrane with a cloth?<\/summary>\n<p style=\"padding: 14px 18px; margin: 0; color: #555; line-height: 1.6; border-top: 1px solid #e5e7eb;\">Dabbing yes, rubbing no. Rubbing leaves fine scratches and charges the glass statically. A statically charged membrane shows readings that wander for minutes, a fault pattern often mistaken for a device defect. Take a soft, lint free cloth and only dab off the remaining moisture.<\/p>\n<\/details>\n<details style=\"border: 1px solid #e5e7eb; border-radius: 8px; margin-bottom: 8px; overflow: hidden;\">\n<summary style=\"padding: 14px 18px; cursor: pointer; font-weight: 600; font-size: 1.05em; background: #fafafa; list-style: none;\">How long does a pH electrode last with good care?<\/summary>\n<p style=\"padding: 14px 18px; margin: 0; color: #555; line-height: 1.6; border-top: 1px solid #e5e7eb;\">One to two years as a rule of thumb. What decides it is storage in KCl solution, rinsing after every use and the kind of samples involved, since heavily loaded or hot media shorten the life noticeably. Apera gives six months of warranty on the electrode and two years on the meter.<\/p>\n<\/details>\n<\/article>\n","protected":false},"excerpt":{"rendered":"<p>Most pH electrodes do not die of wear, they die of bad storage. What the glass membrane actually needs, and which well meant habits ruin it.<\/p>\n","protected":false},"author":1,"featured_media":295355,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"rank_math_title":"Storing a pH Electrode: the 5 Costliest Mistakes","rank_math_description":"Storing a pH electrode correctly: why distilled water destroys it, how to clear a blocked junction and how to tell when a replacement is due.","rank_math_focus_keyword":"store pH electrode","footnotes":""},"categories":[164],"tags":[],"class_list":["post-295324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-pl"],"_links":{"self":[{"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/posts\/295324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/comments?post=295324"}],"version-history":[{"count":0,"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/posts\/295324\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/media\/295355"}],"wp:attachment":[{"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/media?parent=295324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/categories?post=295324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/drain-master.de\/en\/wp-json\/wp\/v2\/tags?post=295324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}